Old and new seismic standards
Japan's seismic standards (耐震基準, taishin kijun) are the structural rules in the Building Standard Act that set how well buildings must withstand earthquakes. They have been tightened after major disasters, and buildings are commonly classed by the standard in force when their construction was approved. A building approved before June 1981 falls under the old standard (kyu-taishin), and one approved from June 1981 onward falls under the new standard (shin-taishin).
The new standard introduced in 1981 aims for buildings to suffer almost no damage in moderate earthquakes of around upper 5 on Japan's seismic intensity scale, and not to collapse in a way that endangers lives in rare, very strong quakes of upper 6 to 7. For wooden houses it raised the amount of bracing walls required. After the 1995 Great Hanshin-Awaji Earthquake, the rules for wooden houses were clarified again in 2000, specifying how foundations and joints must be built. Wooden houses built between 1981 and 2000 are sometimes called "gray zone" houses, because they meet the 1981 standard but not the 2000 rules.
Lessons from the Noto earthquake
The Noto Peninsula earthquake of January 1, 2024, tested these standards. A committee set up by national research institutes analyzed damage to wooden buildings in hard-hit areas. In its November 2024 interim report, 19.4 percent of wooden buildings built before 1981 had collapsed, compared with 5.4 percent of those built from 1981 to 2000 and 0.7 percent of those built after 2000, a pattern similar to that seen in the 2016 Kumamoto earthquakes. The committee concluded that the stricter standards had been effective in preventing collapse. Counting severe damage as well as collapse, about 39 percent of old-standard wooden houses were badly damaged, against about 17 percent of gray zone houses and 2 percent of houses built after 2000.
Retrofitting and tighter checks
The government estimates that about 90 percent of Japan's roughly 55.7 million homes had adequate earthquake resistance in 2023, leaving about 5.7 million without it. The rate was about 85 percent for detached houses and 96 percent for apartment buildings. The land ministry, MLIT, aims to largely eliminate homes with insufficient resistance by 2035 and supports seismic diagnosis and retrofitting, with the expected Nankai Trough megaquake among the reasons.
Checks on new homes have also been tightened. Until 2025, small wooden houses designed by a licensed architect were exempt from structural review at the building confirmation stage, under the so-called "No. 4 special exception". From April 2025 that exemption was narrowed, and builders of two-story wooden houses must now submit structural and energy-efficiency documents when applying for approval.
Sources
- Forestry Agency: Seismic standards and wooden houses (in Japanese)
- Fukuoka Prefecture: Summary of the interim report of the committee analyzing structural damage to buildings in the 2024 Noto Peninsula earthquake (in Japanese; November 2024)
- Kanagawa Prefecture: What are gray zone wooden houses? (in Japanese; updated May 26, 2026)
- Ministry of Land, Infrastructure, Transport and Tourism: Trends in the earthquake resistance rate of housing (in Japanese)
- Ministry of Land, Infrastructure, Transport and Tourism: The No. 4 special exception changes from April 2025 (in Japanese)